Ethanol · Hydrocarbon · Solventless
Botanical Extraction Systems for Commercial Processors
Four numbers decide the platform: daily throughput, solvent recovery architecture, the area classification the process triggers, and how much post-processing sits downstream.
Specifying botanical extraction systems is a choice between ethanol, hydrocarbon and solventless platforms — and the right answer depends on the material, the target output format and the room you can actually build, not on which method a vendor happens to sell. MACH Technologies designs, fabricates, assembles and tests all three families in one vertically integrated Michigan facility, which is why this page compares them instead of defending one. Systems are built to CE, IECEx, UL 508A, PSI and ASME compliance marks and sold nationally across the United States, with international installs.
- CE
- IECEx
- UL 508A
- PSI
- ASME
Ethanol, Hydrocarbon and Solventless Compared on the Same Four Axes
The same decision axes applied to all three platforms, including the cases where each one is the wrong choice.
Most comparisons on this topic are written by a vendor who builds one thing. MACH builds all three, so the axes below are applied identically to each platform. Throughput bands are configuration-dependent and are described here as architecture rather than as fixed figures — the published range on each model or series page is the number to specify against.
| Platform | What scales throughput | Solvent recovery architecture | Area classification burden | Downstream post-processing | Operator load and automation | Applicable marks |
|---|---|---|---|---|---|---|
| Ethanol — EES Series automated, M Series semi-automated | Continuous chilling duty, centrifugation and recovery rate; vessel volume is rarely the ceiling | Integrated recirculation, particle filtration and automated discharge of recovered ethanol and concentrated oil; see solvent recovery in botanical processing | Flammable-liquid handling and associated electrical scope; determined site by site | Heaviest — winterization, filtration, decarboxylation and distillation typically follow | Recipe-driven automated control on EES; higher operator involvement on M Series | UL 508A, PSI, CE, IECEx |
| Hydrocarbon — AHES-40 automated, MHES-20 operator-driven | Pressure rating and recovery speed between runs; see how to specify closed loop extraction systems | Closed-loop recovery with pressure-rated vessels and columns | Heaviest of the three — classified-area requirements and pressure-vessel construction drive room design | Moderate — often routes to crystallization or distillation depending on target output | AHES automates cycles and recovery; MHES is deliberately operator-driven | ASME, PSI, UL 508A, CE, IECEx |
| Solventless — TSS-300, ATS Pro trichome separation | Wash cycle time, water and ice handling, and drying capacity; see how modern trichome separation works | None — no solvent to recover | Lightest — removes solvent handling and its classification implications from the room | Lightest — output is typically finished or press-ready without solvent removal | Highest labor per pound; ATS Pro automates the dry-sift separation step | UL 508A, CE, IECEx |
The honest version of each wrong-fit case: ethanol is the wrong choice when the target output depends on volatile fractions that a heavy winterization-and-distillation train will strip, or when the operation cannot support the chilling and recovery utility load — our own flagship line included. Hydrocarbon is the wrong choice when the facility cannot classify a room and the schedule or budget will not carry pressure-vessel and classified-enclosure scope. Solventless is the wrong choice when the business case is built on yield per pound of feedstock rather than on output character, because it will not compete on mass recovery with either solvent platform.
Throughput, yield, purity and solvent recovery figures vary with input material, system configuration and process parameters. Published figures are not a guarantee of results.
System Families We Design and Build
Four platform families, all engineered, fabricated and tested in one Michigan facility.
-
Ethanol Extraction Systems — EES and M Series
Automated and semi-automated modular ethanol platforms built around continuous chilling and recovery. Specified by processors scaling daily biomass volume. EES Series ethanol extraction systems
-
Hydrocarbon Extraction Systems — AHES and MHES Series
Pressure-rated closed-loop systems, automated or operator-driven. Specified where output character and recovery speed drive the process. AHES-40 automated hydrocarbon system
-
Solventless and Trichome Systems — TSS Series and ATS Pro
Cold-water hash production and automated trichome separation. Specified where solvent handling is off the table. TSS-300 trichome separation system
-
Post-Processing and Refinement Systems — WFDS, TES, DMU, DS
Wiped film and terpene distillation, crystallization and decarboxylation for the train downstream of extraction. WFDS-1S wiped film distillation system
Because we build all four platforms, the method comparison on this page is not weighted toward a single technology we happen to sell.
Sizing a System: Throughput, Recovery Rate and the Real Ceiling
Size from biomass per production day, then work backward. Batch capacity alone will mis-specify the line.
Start with the number the business plan actually commits to: pounds of botanical material processed per production day, at the shift pattern you can staff. Batch capacity is a component of that number, not a substitute for it. A vessel sized for a large single charge means nothing if the line cannot turn that charge over enough times per shift, and that turnover is set downstream of extraction, not inside the vessel.
On most ethanol platforms the practical throughput ceiling is solvent recovery rate. Extraction is fast; getting the ethanol back so the next run can start is not. This is the figure most often misread on a spec sheet, because a large vessel volume reads as capacity while the recovery module quietly sets the cycle time. Specify the two together, and ask for recovery rate under the same configuration and feedstock loading you intend to run. Our deeper reads on measuring and scaling extraction system throughput and solvent recovery in botanical processing walk through the arithmetic.
Chilling duty, filtration capacity and winterization hold time have to be planned in the same pass. Solve recovery in isolation and the bottleneck simply moves — usually to the cold room or to filter changeouts. The constraints interact, and they interact differently at each scale; hold time, chilling and filter capacity in ethanol winterization covers where that typically breaks first.
Batch versus continuous is a throughput architecture decision, not a preference. Continuous architectures smooth utility draw and reduce per-pound labor at sustained volume; batch architectures are simpler to validate, easier to run at variable volume, and often the correct answer for a facility with mixed feedstock or intermittent runs. Batch vs. continuous extraction systems sets out the labor and utility profiles side by side.
Automation is what makes a high-throughput line repeatable with the staff you have. On our automated platforms the control system manages temperature setpoints, pump operation, cycle sequencing, recirculation, particle filtration, solvent recovery, discharge and alarm states under a recipe-driven program — see benefits of automated solvent recovery. Operations already running at scale should start from high capacity botanical extraction systems. If you are earlier in the process, how botanical extraction systems work covers the equipment train end to end.
Throughput, yield, purity and solvent recovery figures vary with input material, system configuration and process parameters. Published figures are not a guarantee of results.
Facility & Compliance Planning
How the System You Choose Determines the Room You Build
Specify the equipment before the room is locked — not after the drawings are stamped.
- UL 508A
- ASME BPVC VIII-1
- PSI Rated
- CE
- IECEx
The platform decision is also a building decision. Hydrocarbon solvent handling drives classified-area requirements and pressure-vessel construction. Ethanol drives flammable-liquid handling and the associated electrical scope. Solventless largely removes both from the room. Facilities that lock layout, ventilation and electrical scope before selecting equipment routinely redesign the room a second time.
Classification itself is site-specific. Under the federal electrical standard for hazardous (classified) locations, each room, section or area is evaluated individually against the flammable vapors, liquids or gases present and the likelihood of a flammable concentration — it is a property of the space and the process, not of a machine. Class I Division 1 and Division 2 determinations are made with your Authority Having Jurisdiction and a registered professional engineer. No equipment vendor, MACH included, can make that determination for you. Which classification your process actually triggers explains how the two differ in practice.
What the marks on our equipment actually cover, rather than a badge wall: UL 508A applies to the industrial control panels we build; ASME governs pressure-vessel design, fabrication, inspection, testing and certification under BPVC Section VIII, Division 1 for vessels operating above 15 psig; PSI denotes the rated pressure of the vessel; CE and IECEx support international deployment. Those are the marks we claim, and the only ones we claim.
A compliance-mark row on a vendor's web page is not the same thing as documentation an inspector will accept. Ask what travels with the equipment: panel listings, vessel documentation, drawings and the specification inputs your engineer of record needs. Where the base building cannot be classified, EE-2 Series extraction enclosures are an alternative to reworking the structure; C1D1 and C1D2 classified enclosure systems covers how they are applied, and botanical extraction equipment and GMP lab standards is the wider standards reference for teams designing to GMP expectations. For hydrocarbon specifics, see specifying and verifying a commercial hydrocarbon system.
Extraction equipment must be installed, permitted, and operated in accordance with all applicable federal, state, and local fire, building, and electrical codes, including Class I Division 1 requirements where applicable. Consult your Authority Having Jurisdiction (AHJ) before installation.
One Engineering Owner From Layout to Installed System
Designed, fabricated, assembled and tested in our vertically integrated Michigan facility.
Search this category and most of what comes back is a distributor assembling third-party equipment into a quote, or a manufacturer that builds one method and argues that method is always correct. Neither can own the integration. When extraction, solvent recovery and refinement come from three suppliers, the seams between them belong to nobody, and the processor discovers that during commissioning.
MACH designs, fabricates, assembles and tests its systems in one vertically integrated Michigan facility. That means one engineering owner across the extraction platform, the recovery module and the downstream refinement train — wiped film distillation, terpene distillation, decarboxylation and crystallization included. Interfaces, utility loads and control logic are resolved on our floor rather than on yours. Our vertically integrated Michigan facility is where every system is built before it ships.
Turnkey lab design and buildout is a distinct offering, and it is the right starting point for a facility still in drawings. We work from the production plan to equipment specification, floor layout and utility loads, so those numbers are fixed before construction begins rather than negotiated against a stamped drawing set. That sequencing is what keeps project engineers from redesigning the room twice.
After the crate: installation, operator training and on-demand technical support are part of the offer, not an upsell. Training matters more on capital equipment than most buyers weight it — a system that requires a specialist to run safely is a system that stops when that person leaves. Installation, operator training and technical support covers the scope.
We supply licensed processors, multi-state operators, contract processors, and essential oil, nutraceutical and other botanical and biomass operations nationally, with international installs.
Where the single-owner scope applies
- Extraction, recovery and refinement engineered as one train
- Floor layout and utility loads fixed before construction
- Fabrication, assembly and test under one roof in Michigan
- Installation, operator training and on-demand technical support
MACH Technologies manufactures and sells processing equipment. It does not process, toll, test, or sell any botanical end product. It is not a general contractor or building trade — it designs lab layouts and equipment.
Get a System Sized to Your Production Plan
Bring your target daily throughput, material type and intended output format. You leave the conversation with a platform recommendation, the sizing logic behind it, and the classification implications — before you commit to a room. You speak with an engineer, not a call center.