Ethanol boils at 78.35 °C (173 °F) at one atmosphere of pressure, according to the NIST Chemistry WebBook, which lists its normal boiling temperature as 351.5 K. It evaporates at every temperature below that as well, which is the distinction that separates a trivia answer from a process specification.
If you are sizing a solvent recovery train, that single number is the least useful thing on the page. What you actually need is the relationship between absolute pressure, surface temperature, and residence time, and the four spec-sheet figures that relationship produces. This article works through both.
What temperature does alcohol evaporate at?
Ethanol boils at 78.35 °C (173 °F) at one atmosphere and evaporates at any temperature at which it stays liquid. Under vacuum that boiling point falls to approximately 34 °C, which is why solvent recovery is specified by pressure, not by heat.
What is ethanol's boiling point at one atmosphere?
Ethanol boils at 78.35 °C (173 °F) at standard atmospheric pressure. The NIOSH Pocket Guide to Chemical Hazards lists ethyl alcohol (CAS 64-17-5) with a boiling point of 173 °F and a vapor pressure of 44 mmHg at 68 °F, which is the second number to write down. That vapor pressure at room temperature is the whole reason the boiling point alone tells you so little.
What is the difference between ethanol evaporating and ethanol boiling?
Boiling is a bulk phase change that happens at a defined temperature, when the liquid's vapor pressure equals the pressure above it and vapor forms throughout the liquid. Evaporation is a surface process, and it happens at any temperature at which ethanol is liquid. A drum of 190 proof sitting open at 20 °C is evaporating right now. Nobody applied heat.
Every consumer page ranking for this query blurs those two things together and then answers a cooking question. On a production floor they are separate variables with separate controls.
How does ethanol's boiling point compare to water and isopropyl alcohol?
Water boils at 100 °C (212 °F), roughly 22 °C above ethanol, which is the gap that makes ethanol-water separation by distillation possible in the first place. Isopropyl alcohol boils near ethanol's range and shows up constantly in this search result set, but it is a different solvent with different hazard and residue behavior and is not interchangeable in a botanical extraction process.
From here, this page addresses ethanol as a process solvent in commercial botanical and biomass extraction. Not as a cooking ingredient, and not as a beverage input. For a broader definition of the term and the solvent stream it describes, see our explainer on what ethanolic means.
Does ethanol evaporate at room temperature?
Yes. Ethanol evaporates at every temperature at which it is liquid, because evaporation is a surface process governed by vapor pressure rather than by a threshold. NIOSH lists ethyl alcohol with a vapor pressure of 44 mmHg at 68 °F.
Two consequences follow at ambient temperature, before any heater is switched on: solvent leaves open transfers and unsealed vessels continuously, and vapor accumulates in the room. Both are handled in detail below, as a recovery problem and as a flash point problem.
Why is a single evaporation temperature the wrong mental model for a process engineer?
Because ethanol has measurable vapor pressure far below 78 °C. Loss rate is set by vapor pressure, containment, and transfer design, not by whether the liquid has reached a stated temperature.
Why does vapor pressure matter more than a threshold temperature?
Ethanol has measurable vapor pressure far below 78 °C, and that vapor pressure, not a threshold temperature, governs how fast you lose solvent. This is why open transfers, unsealed tincture vessels, partially closed drum bungs, and slow manual decanting all bleed solvent continuously without anyone touching a heater.
Where does room-temperature evaporation show up in equipment terms?
In equipment terms, that loss shows up in two places. It is a consumables line — make-up solvent you purchase every month — and it is the reason vapor accumulates in a room that is not actively ventilated. Both consequences exist at ambient temperature, before the process begins.
The question worth asking on a plant floor is not "what temperature does it evaporate." It is: at what rate, into what containment, and recovered to where.
What does uncontrolled evaporation cost a production lab?
We will not put a percentage on it, because the honest answer depends on your transfer design, your vessel closures, and your cycle count. What we can say is that the losses are structural rather than incidental, and closed-transfer architecture addresses them more reliably than operator discipline does. That principle is covered in more depth in our overview of solvent recovery in botanical processing.
Three variables control the whole problem, and the rest of this article handles them as spec axes: absolute pressure, heat-transfer surface temperature, and residence time.
At what temperature does ethanol boil under vacuum?
Under vacuum, ethanol's boiling point falls from approximately 78 °C to approximately 34 °C — a 44 °C swing produced by pressure control alone. Absolute pressure, not applied heat, sets the temperature your feed actually sees.
What does vacuum do to ethanol's boiling point?
Under vacuum, ethanol's boiling point falls from approximately 78 °C to approximately 34 °C, according to The Open University, which describes this as the standard route to removing solvent before heat-sensitive volatile components are affected. That is a 44 °C swing produced by nothing but pressure control.
The mechanism is straightforward at principle level. Reducing the absolute pressure above the liquid reduces the vapor pressure the liquid must reach in order to boil, so it boils cooler. The governing relationships are the Clausius-Clapeyron relationship and the Antoine equation, and NIST publishes Antoine coefficients for ethanol if your process engineer wants to model the curve for your specific operating window.
Ethanol boiling point versus absolute pressure: the two cited reference points
The two operating points cited on this page are set out below. They are reference points, not a full pressure-temperature curve: intermediate values belong to your own operating window and should be modelled from the NIST Antoine coefficients and confirmed against site barometric pressure.
| Absolute pressure | Ethanol boiling temperature | Source cited on this page |
|---|---|---|
| One standard atmosphere (760 Torr / 1,013 mbar, sea level reference) | 78.35 °C (173 °F); 351.5 K | NIST Chemistry WebBook; NIOSH Pocket Guide lists 173 °F |
| Under vacuum (reduced absolute pressure; depth not stated by the source) | Approximately 34 °C | The Open University |
| Your stated operating vacuum, in Torr, mbar, or inHg absolute | Model from the Antoine coefficients for ethanol, then confirm against site barometric pressure | NIST publishes Antoine coefficients for ethanol |
Whatever pressure you land on, state it as absolute rather than gauge, and state the units with it. A vacuum figure without units or without an absolute reference cannot be compared between two quotes.
Why does a lower boiling temperature protect volatile target compounds?
Lower process temperature means less thermal exposure for heat-sensitive target compounds and volatile aromatic compounds moving through the system. That is an equipment-performance argument, not a product claim: the same mass of feedstock spends less time against a hot surface. Our article on how ethanol extraction temperature affects efficiency and consistency works through the upstream side of that same trade.
Site conditions shift the curve too. Barometric pressure at your altitude changes the atmospheric reference point, so confirm boiling behavior against your site rather than against a sea-level table.
Which four numbers replace "the evaporation temperature" on a real spec sheet?
On a quote, "the evaporation temperature" resolves into four figures:
- Operating absolute pressure — the vacuum depth the system holds in continuous service, stated in Torr, mbar, or inHg, and stated as absolute rather than gauge.
- Jacket or heat-exchanger supply temperature — the range the heating medium is delivered at, not the bulk liquid temperature.
- Condenser coolant temperature and available delta-T — what the chiller supplies and what temperature difference the condenser actually works with.
- Feed rate and residence time — how long any given volume of feed is in contact with the heated surface.
There is a pairing rule buried in that list. You cannot specify a vacuum level without specifying condenser capacity alongside it, because vapor you cannot condense is vapor you do not recover. It leaves through the vacuum pump instead, and it shows up as both a solvent loss and a vapor handling question.
Why does recovered ethanol come back at roughly 190 proof?
Because ethanol and water form an azeotrope at 95.6 percent ethanol. Distilling any weaker mixture cannot produce pure ethanol, so recovered solvent returns near 190 proof and reaching 200 proof requires a separate unit operation.
What is an azeotrope?
An azeotrope is a liquid mixture whose vapor has the same composition as the liquid it came from, which means further distillation stops changing the ratio. Britannica describes the minimum-boiling case and the standard routes around it: entrainers, pressure-swing distillation, and pervaporation. Ethanol and water form exactly that kind of mixture.
What does the 95.6 percent wall mean for reproofing?
It is impossible to obtain pure ethanol by distilling any ethanol-water mixture containing less than 95.6 percent ethanol, because at that composition the vapor and the liquid have identical composition, as LibreTexts states directly. Practically, recovered solvent returns near 190 proof, not 200 proof.
That has consequences across cycles. Water accumulates in the recovered stream, proof drifts, and a system running on drifting proof runs a slightly different extraction every week. Molecular sieve dehydration, entrainer-based separation, and pressure-swing distillation each bypass the ceiling, and each is a separate unit operation with its own footprint and its own operating cost. Name them as awareness items in your planning, not as a checkbox on a solvent recovery quote.
Why does proof verification belong in your documentation package?
Ask any vendor a specific question: how is solvent proof verified between cycles, who logs it, and is that log part of the delivered documentation package? A batch still or a simple distillation setup can hit the same composition limit as an engineered recovery train. The difference between them is whether the result is measured, recorded, and traceable. Our piece on why solvent recovery equipment anchors the lab makes the case for treating recovery as core infrastructure rather than downstream cleanup.
What is ethanol's flash point, and why does it matter below the boiling point?
NIOSH lists ethyl alcohol with a flash point of 55 °F (about 13 °C), below normal room temperature. An ethanol lab therefore generates ignitable vapor at rest, long before anything is heated toward the 173 °F boiling point.
What are ethanol's flash point, flammable-liquid class, and explosive limits?
The NIOSH Pocket Guide lists ethyl alcohol with a flash point of 55 °F, a lower explosive limit of 3.3 percent and an upper explosive limit of 19 percent, classifying it as a Class IB flammable liquid. Read that first number against your room. The flash point is below normal ambient temperature, which means an ethanol lab generates ignitable vapor at rest, long before anything is heated toward 173 °F.
That reframes ventilation, vapor detection, and hazardous-location-rated equipment as baseline conditions rather than precautions that apply only during the heating stage.
How does ethanol vapor behave differently than the liquid?
Ethanol vapors are heavier than air and can travel to a remote ignition source, according to NOAA CAMEO Chemicals, which also notes that ethanol can burn with a nearly invisible flame. Vapor collects at floor level, moves along drains and trenches, and finds ignition sources that are nowhere near the vessel it escaped from. Detection mounted at breathing height is measuring the wrong layer of the room.
What determines the electrical classification of your room?
Classification is determined by your process and your room, not by the machine you buy. No equipment purchase changes the division your operation triggers. What equipment selection does control is whether the motors, pumps, and instrumentation inside the classified area are listed for the service they are installed in.
MACH builds to CE, IECEx, UL 508A, PSI, and ASME marks, and we specify hazardous-location-rated components where the classified area calls for them. We make no certification claim beyond those five. If you are still working out which classification applies, start with which classification your process actually triggers, then confirm the specifics with your Authority Having Jurisdiction and fire marshal. Permitting requirements vary by jurisdiction.
How do you turn evaporation temperature into a solvent recovery specification?
Replace the single temperature with four stated figures — operating absolute pressure, jacket or heat-exchanger supply temperature, condenser coolant temperature and delta-T, and feed rate with residence time — then require the test conditions behind every performance number.
Which spec axes should you compare across vendors?
Hold two competing quotes against the same axes and the differences become visible fast:
| Spec axis | What to require |
|---|---|
| Operating vacuum | Absolute pressure with units stated (Torr, mbar, inHg), not gauge |
| Jacket / heat-exchanger supply | Temperature range of the heating medium |
| Condenser and chiller | Coolant supply temperature and rated chiller capacity |
| Rated throughput | Feed ratio and feed condition it was measured at |
| Recovery efficiency | The full test conditions attached to the number |
| Vessel pressure rating | Rating and the scope of ASME work |
| Control panel | UL 508A listing and short-circuit current rating |
| Rotating and sensing equipment | Hazardous-location rating of pumps, motors, instrumentation |
What should you ask before a quote is signed?
A throughput number without conditions is a marketing figure. Ask what feed dilution ratio it was measured at, whether the feed was dewaxed, what the inlet temperature was, and what vacuum level the system held during the test. A recovery efficiency quoted without those conditions cannot be compared against anyone else's.
Then ask what happens after delivery. Installation, operator training, and on-demand technical support are part of what we sell, and they belong in your evaluation criteria. A system that needs heavy operator judgment to hold a vacuum setpoint carries a training cost that never appears on the quote.
What belongs in the documentation package?
Ask for the package in writing before signing: pressure vessel documentation and ASME scope, control panel drawings and the UL 508A listing, the component list with hazardous-location ratings, P&IDs, and the test conditions behind every performance figure. Our automated solvent recovery systems, including the ASR-75 solvent recovery system, ship with that documentation as part of the delivery, alongside the EES Series ethanol extraction systems, CES Series centrifuge extraction systems, and WFDS Series wiped film distillation systems they are specified with.
Every one of those systems is designed, fabricated, assembled and tested in our vertically integrated Michigan facility and sold nationally.
Which recovery architecture fits your temperature and time curve?
Compare recovery architectures on two axes and the choice gets simpler: the process temperature the architecture requires, and how long the feed sits at that temperature.
When does rotary evaporation fit, at lab and pilot scale?
Batch operation, high surface-area-to-throughput ratio, and well understood at lab and pilot scale. The failure mode is scaling by multiplication. Adding units adds floor space, labor, and per-batch variability, and the temperature and residence time picture stops improving.
When is falling film evaporation the right choice for production volume?
Continuous or semi-continuous, with feed spread as a thin film over heated tubes under vacuum. Contact time between feed and heated surface is short, and capacity scales with heat-transfer surface area rather than with headcount. Fouling and foaming are the practical failure modes under deep vacuum, so ask about vapor-liquid separation design and CIP provisions before you ask about throughput. If your volume question starts upstream, how to size an ethanol centrifuge extraction system and scaling ethanol winterization cover the feed side of the same decision.
Where do wiped film and short path sit in the process?
Wiped film and short path sit at the refinement stage, not at bulk solvent removal. They operate at deeper vacuum with very short residence time and are specified for separating target compounds after the solvent is already gone. See wiped film distillation for botanical refinement and specifying short path distillation equipment for the spec axes that apply there.
Bulk solvent removal and refinement are two different jobs on the temperature-time curve. Systems built for one are not substitutes for the other, which is why our ethanol extraction systems are specified as a train rather than a single machine.
What does this set in your spec?
On an EES Series ethanol extraction train, the solvent-recovery surface is specified by absolute pressure, heat-transfer surface temperature, and residence time — not by a single evaporation temperature. Everything above resolves into the following requirements on a quote.
- State vacuum as absolute pressure, with units. Ethanol boils at 78.35 °C at one atmosphere and at approximately 34 °C under vacuum, so the pressure figure — in Torr, mbar, or inHg absolute — is what fixes your process temperature.
- Pair every vacuum figure with condenser capacity. Vapor you cannot condense is vapor you do not recover; it leaves through the vacuum pump as both a solvent loss and a vapor handling question.
- Plan for 190 proof, not 200. The 95.6 percent ethanol-water azeotrope caps what distillation returns, so molecular sieve dehydration, entrainer-based separation, or pressure-swing distillation is a separate unit operation with its own footprint and operating cost.
- Set the room on the flash point, not the boiling point. Ethyl alcohol flashes at 55 °F, below ambient, so ventilation, vapor detection at floor level, and hazardous-location-rated rotating and sensing equipment are baseline conditions.
- Size by heat-transfer surface, not by unit count. Falling film capacity scales with heat-transfer surface area rather than with headcount, which is why adding rotary units multiplies floor space and variability instead of improving the temperature and residence time picture.
- Require the documentation in writing before signing. ASME scope, UL 508A control panel listing and short-circuit current rating, component hazardous-location ratings, P&IDs, and the test conditions behind every throughput and recovery figure.
Classification remains a property of your process and your room, confirmed with your Authority Having Jurisdiction and fire marshal, not a property of the equipment you buy.
Frequently asked questions about ethanol evaporation temperature
Does alcohol evaporate at room temperature?
Yes. Ethanol evaporates at any temperature at which it is liquid, because evaporation is a surface process driven by vapor pressure rather than a threshold event. NIOSH lists ethyl alcohol with a vapor pressure of 44 mmHg at 68 °F, which is why open vessels and unsealed transfers lose solvent continuously without any heat applied.
At what temperature does ethanol evaporate under vacuum?
Under vacuum, ethanol's boiling point falls from approximately 78 °C to approximately 34 °C, according to The Open University. The exact figure depends on the absolute pressure your system holds, so specify vacuum depth in absolute units and pair it with condenser coolant temperature. Vapor you cannot condense is vapor you do not recover.
Why can't distillation produce ethanol stronger than about 95.6 percent?
Because ethanol and water form an azeotrope. LibreTexts states that it is impossible to obtain pure ethanol by distilling any mixture containing less than 95.6 percent ethanol, since at that composition vapor and liquid have identical composition. Recovered solvent therefore returns near 190 proof, and reaching 200 proof requires a separate unit operation.
Is ethanol vapor flammable below its boiling point?
Yes. NIOSH lists ethyl alcohol with a flash point of 55 °F, below normal room temperature, and a lower explosive limit of 3.3 percent. Ignitable vapor is present at ambient conditions, well before anything is heated toward 173 °F, and that vapor is heavier than air and collects at floor level.
Talk to our engineers about your recovery train
If you are building a specification and want the four numbers filled in against your actual feed volume, our engineering team will work the sizing with you and put the documentation scope in writing before anything is quoted. Send us your feed ratio, target throughput, and room classification, and we will tell you what the temperature and time curve looks like for your process.
MACH Technologies manufactures and sells processing equipment. It does not cultivate, produce, sell, or distribute hemp or any botanical end product.
Extraction equipment must be installed, permitted, and operated in accordance with all applicable federal, state, and local fire, building, and electrical codes, including Class I Division 1 requirements where applicable. Consult your Authority Having Jurisdiction (AHJ) before installation.
Throughput, yield, purity, and solvent recovery figures vary with input material, system configuration, and process parameters. Published figures are not a guarantee of results.
Operators are responsible for verifying that their intended use is lawful in their jurisdiction.